Landlords in England, Wales, Scotland and Northern Ireland must have the electrical installation in a rented home inspected and tested by a qualified person at least every 5 years, and give tenants a copy of the report. In England you must give existing tenants the report within 28 days, fix any C1, C2 or FI items within 28 days (or sooner if the report says so), and councils can fine you up to £30,000 for breaches.
What the law requires in England
The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 apply to tenancies granted since 1 July 2020, and to all existing tenancies since 1 April 2021. You must:
- Make sure the national electrical safety standards (BS 7671) are met while the property is let.
- Have the installation inspected and tested by a qualified and competent person at least every 5 years.
- Get a written report and give a copy to each existing tenant within 28 days of the inspection.
- Give a copy to any new tenant before they move in, and to a prospective tenant within 28 days of them asking.
- Give a copy to the council within 7 days if it asks for one.
- Keep a copy to give to the inspector who carries out the next inspection.
- Complete any remedial or further investigation work within 28 days, or sooner if the report says, and send written confirmation to the tenant and the council within 28 days of the work being finished.
Councils can serve remedial notices, do the work themselves and recover the cost, and impose civil penalties of up to £30,000. Since 1 December 2025 the same duties also apply to new social housing tenancies, and to all existing social tenancies since 1 May 2026. See EICRs for social housing.
Wales, Scotland and Northern Ireland
| Nation | Rule | Key differences |
|---|---|---|
| Wales | Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022 | Report at least every 5 years; copy to the contract-holder within 14 days of occupation or of the inspection. |
| Scotland | Repairing Standard, Housing (Scotland) Act 2006 | EICR at least every 5 years plus PAT testing of appliances the landlord supplies. |
| Northern Ireland | Electrical Safety Standards for Private Tenancies Regulations (NI) 2024 | New tenancies from 1 April 2025; all private tenancies from 1 December 2025. |
Full guides: Wales · Scotland · Northern Ireland.
How much does a landlord EICR cost?
| Property | Typical price | Typical time on site |
|---|---|---|
| Studio, 1 or 2-bed flat | £120–£200 | 1–2 hours |
| 3-bed house | £200–£250 | 2–3 hours |
| 4-bed house or larger | £250–£350 | 3–4 hours |
| HMO | Quoted on circuits and boards | Half a day or more |
London and the South East are typically around 20–30% higher. More in the EICR cost guide.
Built or rewired in the last 5 years?
If the property was built or fully rewired in the last 5 years, you can give tenants the Electrical Installation Certificate (EIC) instead, and the next inspection is due 5 years from the date on it. See EIC vs EICR.
If the report is unsatisfactory
Any C1, C2 or FI observation makes the report unsatisfactory. Book the remedial work, get written confirmation from the electrician (usually a Minor Works Certificate or an EIC), then send it with the original report to your tenants and the council within 28 days of completing the work. Step by step: what to do if your EICR fails.
Other landlord safety certificates
The EICR sits alongside the annual gas safety record, the EPC and smoke and carbon monoxide alarm rules. See the landlord certificates checklist.
Frequently asked questions
How often do landlords need an EICR?
At least every 5 years in all four UK nations, or sooner if the previous report recommends a shorter interval.
Do I need a new EICR for every new tenant?
No. In England a report remains valid for the interval it states, up to 5 years. Give each new tenant a copy of the current report before they move in.
Is PAT testing a legal requirement for landlords?
In Scotland, yes, for appliances the landlord supplies. In England it isn’t required for private landlords, but social landlords must include appliances they supply, and it’s good practice for everyone.
Can my letting agent arrange the EICR?
Yes, but the legal duty stays with you as the landlord. Make sure you get a copy of the report and know the next due date.
What happens if I don’t have an EICR?
In England the council can serve a remedial notice, arrange the work and recover the cost, and impose civil penalties of up to £30,000.
Related guides
Sources
- legislation.gov.uk: The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020
- GOV.UK: Guide for landlords – electrical safety standards in the private rented sector
- legislation.gov.uk: Extension to the Social Rented Sector Regulations 2025 (SI 2025/1043)
- legislation.gov.uk: Renting Homes (Fitness for Human Habitation) (Wales) (Amendment) Regulations 2022
- gov.scot: Repairing Standard – statutory guidance on electrical installations and appliances
- Department for Communities (NI): Electrical Safety Standards for Private Tenancies Regulations 2024
- MyBuilder: EICR certificate cost guide (2026)
This guide is general information, not legal advice. Rules differ between England, Wales, Scotland and Northern Ireland.